The BR-MOD-1-9-A-2S (Dual Input) is a full SDR satellite beacon receiver designed on a completely new platform to meet today’s system challenges. It is a robust and reliable product featuring many capabilities to provide rugged and reliable operation in embedded application. A CW satellite beacon carrier can be acquired quickly
and tracked in On-the-Move, as well as in fixed-site applications. It provides a voltage output from 0 to 10 VDC proportional with the input L-band signal. In addition, the receiver can lock on and track BPSK-type carrier signals AND is uniquely capable of locking on and tracking a DVB- like carriers utilizing an exclusive Avcom-only Carrier- EdgePower-Tracking (CEPT) function. Avcom’s EVO-GUI software is included and provides a full- featured set of tools for robust operations for any application. Avcom provides API protocol documentation and support for developing POSIX-C compliant APIs for your application. Please contact salesrfq@avcomofva.com for documentation and support.

PRODUCT DATASHEET

Embedded Extended-Band Dual Input
Beacon Receiver Module

• Track L-Band CW Beacon Carrier; BPSK Carrier
• CEPT-Carrier-Edge-Power-Track for DVB Carrier
• For Integration in On-The-Move Applications
• Monitoring & Control (M&C) via Ethernet with EVO-GUI
• Comprehensive API for Easy Integration
• Extended Temperature Range
• Low SWaP (Size, Weight, and Power)

SKU: BR-MOD-1-9-A-2S-3040 Category: Tag:

PARAMETER

PERFORMANCE

INPUT CONNECTORS: 2 X SMA, 50 Ohm
INPUT FREQUENCY RANGE: 400-3000 MHz
TUNING STEP SIZE: 1kHz
INPUT LEVEL RANGE: -10 to -100 dBm
MAXIMUM INPUT POWER LEVEL: – 10 dBm max
DETECTION BANDWIDTH: 10 to 750 kHz
TRACKING BANDWIDTH: 10 to 150 kHz
DETECTED LEVEL FILTERING: Low-Pass, User-Select: 0.25 Hz, 0.5 Hz, 1.0 Hz, 2.0 Hz, 3.0 Hz
SEARCH/TRACK RATE: User-Selectable: 10 Hz, 25Hz
ACQUISITION TIME: <1 second typical
ADJUSTABLE DELAY BEFORE LOCK: 0 to 5000 milliseconds
ACQUISITION/TRACKING LEVEL: Minimum C/No, 39 dB-Hz
BEACON/CARRIER TYPE: CW, BPSK (No Demod), CEPT(Carrier-Edge-Power-Track) on DVB (No Demod)

M & C

ETHERNET: 10/100; Magnetics on-board, 4-pin Molex
IP ADDRESS: DHCP or Static
INCLUDED CONTROL APPLICATION: Avcom GUI (Windows)
APPLICATION PROGRAMMING INTERFACE (API): POSIX-compliant ‘C’

Pre-built Libraries for Windows and Linux x86 Source code available

PROTOCOL: High-reliability closed-loop with error checking
RECEIVER OUTPUT VIA PHYSICAL OUTPUTS: Yes
RECEIVER OUTPUT VIA M&C INTERFACE: Yes

RECEIVER OUTPUTS

CONNECTOR: 6-pin Molex
ANALOG SIGNAL STRENGTH INDICATOR OUTPUT: 0 to 10 VDC, 25 mA
ANALOG SLOPE: 0.1 to 3.0 Volts/dB
ANALOG SLOPE POLARITY: Positive or Negative
ANALOG OUTPUT FILTERING: Low-Pass, 0.5 Hz, fixed.
DIGITAL LOCK INDICATOR OUTPUT: 0 – 3.3 VDC
DIGITAL LOCK INDICATOR OUTPUT POLARITY: Adjustable (H=LOCK or L=LOCK)

POWER

CONNECTOR: 2-pin Molex
POWER SUPPLY: 15 – 24 VDC; < 3 W

PHYSICAL

DIMENSIONS: 3 in. x 3.5 in. x 1.057 in.
WEIGHT: 8 oz; 200g

ENVIRONMENTAL

OPERATING TEMPERATURE: -40°C to 70°C
STORAGE TEMPERATURE: -40°C to 85°C
HUMIDITY: 0 to 95%, non-condensing
OPERATING ALTITUDE: 40,000 ft; 12,000 m

EVO-GUI Software

  • EVO – GUI Software
  • EVO – GUI User Manual

Download Exe File Download GUI User Manual

Release Notes

    v1.4.2.0
    • Includes all fixes from v1.2.4.0
    • Add 100Hz BR update rate
    • Add external inverted downconverter support
    • Add inverted C-Band downconverter to default LO offset list
    • Add slot 31 to default SA list
    • Fix lo offset not loading correctly bug for br config frequency
    v1.2.4.0
    • Includes all fixes from v1.2.3.0
    • Update sbs2api to v2.13.3.0 (add BR-MOD-1-9-B USB support)
    v1.2.3.0
    • Fix spectrum mode support on old SBS2 units that did not properly support AVCOM_SBS_QueryFeature
    • Fix rbw selection in BR preview mode to make sure rbw is valid
    • Update measured frequency to fix corrected sbs2api unit error
    • Improve graph utilization by getting unit specified dynamic range using AVCOM_SA_GetDynamicRange
    • Fix reconnect bug when using quick connect
    • Fix bug when input was unable to be set
    • Fix bug on set input for SBS1 products with different reflvls
    • Update sbs1api to v1.8.3.0
    • Update sbs2api to v2.10.3.0
    • Update aovhpbasic to v1.3.3.0
    v1.1.6.0
    • Add hw and bom version to analyzer info screen
    • Add Linux build options
    • Update default demo slot names
    • Change default trace color to yellow
    • Remove unused help buttons
    • Fix dB and dBm typos
    • Increase max graph range to 30dBm
    • Add an optional advanced feature menu and full support for sweep optimization within the new menu
    • Update sbs2api to v2.8.4
    • Use AVCOM_BR_GetLatestData over AVCOM_BR_GetLastSweep if BR supports it
    • Add support for changing network settings over USB
    • Add search on all network adapters options to fix most common network search problems
    v1.0.3.0
    • Initial v1.0 Release
 

EVO-GUI (Graphical User Interface)

After installing and running the GUI software, click on the